Lune

UbiComp2026顶会

Acoustoscillogram: Unlocking Arterial Health Insights via Acoustic Sensing with Low-cost Wired Earphones

Xiaoxuan Liang, Zhaolong Wei, Shirui Cao, Quan Zhang, Longfei Shangguan, Dong Li, Jeremy Gummeson

摘要

Cardiovascular disease is a leading cause of mortality worldwide and a major contributor to rising healthcare costs. Early detection of arterial stiffness through metrics such as Pulse Wave Velocity (PWV) and Augmentation Index (AIx) is essential for cardiovascular disease prevention and treatment. However, conventional measurement methods typically require expensive, specialized equipment and clinical settings. In this paper, we explore the use of everyday earphones to monitor PWV and AIx in daily life by capturing skin displacement waveforms induced by arterial pulsation. However, several key challenges must be addressed. First, detecting subtle skin displacement is difficult due to strong self-interference from the speaker to microphone. To address this, we propose a Doppler shift-based displacement estimation approach to isolate dynamic movements from static interference. Second, estimating PWV requires simultaneous two-point measurements, which is non-trivial with standard earphones. We address this with a hardware-software co-design that connects two earphone pairs via a commercial audio splitter and uses orthogonal frequency division multiplexing (OFDM)-based signal separation to extract displacement signals from both sites. Third, enabling general public use without medical training requires thoughtful system design. To this end, we develop a user-friendly mobile application that provides real-time feedback, along with a 3D-printed enclosure to facilitate ease of use and wide accessibility. We conducted IRB-approved clinical studies with 32 participants, comparing our measurements against ground truths from medical devices. Results show that our method achieves a PWV error of less than 0.5 m/s and an AIx error of less than 4%, meeting established medical standards. Please find the demo of our system here .

问 Lune

几分钟读透这篇 Paper,不用再花一下午。

Lune 能读完全文,也能读引用它的顶会 Paper,讲清它的结论、证据和局限,每一点都注明出自哪篇 Paper。不用硬啃,也不靠猜。

可以从这些问题问起

Lune 可以查阅

全文 · 相关的 Paper

获取答案

免费开始,无需绑卡

脉络

它引用的引用它的从左到右按年份排列,引用越多,位置越高。

它引用的 Paper11

  1. Contactless seismocardiography via deep learning radarsUnsoo Ha, Salah Assana, Fadel AdibMobiCom 2020 · 198 次引用
  2. Crisp-BP: continuous wrist PPG-based blood pressure measurementYetong Cao, Huijie Chen, Fan Li, Yu WangMobiCom 2021 · 56 次引用
  3. Your Smart Speaker Can "Hear" Your Heartbeat!Fusang Zhang, Zhi Wang, Beihong Jin, Jie Xiong 等UbiComp 2021 · 47 次引用
  4. APG: Audioplethysmography for Cardiac Monitoring in HearablesXiaoran Fan, David Pearl, Richard E. Howard, Longfei Shangguan 等MobiCom 2023 · 42 次引用
  5. LASense: Pushing the Limits of Fine-grained Activity Sensing Using Acoustic SignalsDong Li, Jialin Liu, Sunghoon Ivan Lee, Jie XiongUbiComp 2022 · 36 次引用

相关 Paper

  1. RF-AE: Single-site Arterial Elasticity Estimation Using UWB SignalsZhi Wang, Beihong Jin, Yuhui Chen, Fusang Zhang 等UbiComp 2025 · 1 次引用
  2. ArtEARial: Arterial Pressure Waveform Reconstruction Using Earbud AudioKenneth Christofferson, Michelle Lin, Joseph A. Cafazzo, Alex MariakakisUbiComp 2026
  3. Continuous Pulmonary Artery Pressure Monitoring using In-ear MicrophoneJunyi Zhou, Chaoyi Sun, Di Fan, Yiyi Zhang 等INFOCOM 2026
  4. HearBP: Hear Your Blood Pressure via In-ear Acoustic Sensing Based on Heart SoundsZhiyuan Zhao, Fan Li, Yadong Xie, Huanran Xie 等INFOCOM 2024 · 11 次引用
  5. RingBP: Towards Continuous, Comfortable, and Generalized Blood Pressure Monitoring Using a Smart RingGuanzhou Zhu, Dong Zhao, Yixuan Song, Zilong Wang 等UbiComp 2025 · 2 次引用
黄昏的海面,两侧是细线勾勒的悬崖