Crisp-BP: continuous wrist PPG-based blood pressure measurement
摘要
Arterial blood pressure (ABP) monitoring using wearables has emerged as a promising approach to empower users with self-monitoring for effective diagnosis and control of hypertension. However, existing schemes mainly monitor ABP at discrete time intervals, involve some form of user effort, have insufficient accuracy, and require collecting sufficient training data for model development. To tackle these problems, we propose Crisp-BP, a novel ABP monitoring system leveraging the PPG sensor available in commercial wrist-worn devices (e.g., smartwatches or fitness trackers). It enables continuous, accurate, user-independent ABP monitoring and requires no behavior changes during collecting PPG data. The basic idea is to illuminate a skin/tissue, measure the light absorption, and characterize ABP-related blood volume change in the artery. To obtain accurate measurements and relieve the pain of training data collection, we use an arterial pulse extraction method that removes interference caused by capillary pulses. Moreover, we design a contact pressure estimation method to combat the deficiency of PPG waveform being sensitive to the contact pressure between the sensor and the skin. In addition, we leverage the great power of Bidirectional Long Short Term Memory and design a hybrid neural network model to enable user-independent ABP monitoring, so that users do not have to provide training data for model development. Furthermore, we propose a transfer learning method that first extracts general knowledge from online PPG data, then use it to improve the learning of a new model on our target problem. Extensive experiments with 35 participants demonstrate that Crisp-BP obtains the average estimation error of 0.86 mmHg and 1.67 mmHg and the standard deviation error of 6.55 mmHg and 7.31 mmHg for diastolic pressure and systolic pressure, respectively. These errors are within the acceptable range regulated by the FDA's AAMI protocol, which allows average errors of up to 5 mmHg and a standard deviation of up to 8 mmHg. Our results demonstrate that Crisp-BP is promising for improving the diagnosis and control of hypertension as it provides continuousness, comfort, convenience, and accuracy.
问 Lune
几分钟读透这篇 Paper,不用再花一下午。
Lune 能读完全文,也能读引用它的顶会 Paper,讲清它的结论、证据和局限,每一点都注明出自哪篇 Paper。不用硬啃,也不靠猜。
已有 8 篇顶会 Paper 引用了它。别等审稿人问起,先弄清它们发现了什么。
脉络
- Guard Your Heart Silently: Continuous Electrocardiogram Waveform Monitoring with Wrist-Worn Motion Sensor 引用了 PPGPass: Nonintrusive and Secure Mobile Two-Factor Authentication via Wearables
- PPGSpotter: Personalized Free Weight Training Monitoring Using Wearable PPG Sensor 引用了 PPGPass: Nonintrusive and Secure Mobile Two-Factor Authentication via Wearables
引用它的顶会 Paper8
- MoVi-Fi: motion-robust vital signs waveform recovery via deep interpreted RF sensingZhe Chen, Tianyue Zheng, Chao Cai, Jun LuoMobiCom 2021 · 190 次引用
- Guard Your Heart Silently: Continuous Electrocardiogram Waveform Monitoring with Wrist-Worn Motion SensorYetong Cao, Fan Li, Huijie Chen, Xiaochen Liu 等UbiComp 2022 · 19 次引用
- LiT: Fine-grained Toothbrushing Monitoring with Commercial LED ToothbrushKaixin Chen, Lei Wang, Yongzhi Huang, Kaishun Wu 等MobiCom 2023 · 13 次引用
- HearBP: Hear Your Blood Pressure via In-ear Acoustic Sensing Based on Heart SoundsZhiyuan Zhao, Fan Li, Yadong Xie, Huanran Xie 等INFOCOM 2024 · 11 次引用
- PPGSpotter: Personalized Free Weight Training Monitoring Using Wearable PPG SensorXiaochen Liu, Fan Li, Yetong Cao, Shengchun Zhai 等INFOCOM 2024 · 4 次引用
它引用的 Paper2
相关 Paper
- RingBP: Towards Continuous, Comfortable, and Generalized Blood Pressure Monitoring Using a Smart RingGuanzhou Zhu, Dong Zhao, Yixuan Song, Zilong Wang 等UbiComp 2025 · 2 次引用
- UWB-enabled Sensing for Fast and Effortless Blood Pressure MonitoringZhi Wang, Beihong Jin, Fusang Zhang, Siheng Li 等UbiComp 2024 · 20 次引用
- MuBP: Multimodel and Continuous Blood Pressure Measurement via UWB-IMU Fusion on Commercial SmartwatchesDongzi Wang, Zhengxin Guo, Linqing Gui, Ming Gao 等INFOCOM 2026
- PracticalBP: Continuous Cuffless Blood Pressure Monitoring with Only One Record for CalibrationChenggao Li, Junyao Peng, Qingyong Hu, Lin Chen 等UbiComp 2025 · 3 次引用
- Contactless Arterial Blood Pressure Waveform Monitoring with mmWave RadarQingyong Hu, Qian Zhang, Hao Lu, Shun Wu 等UbiComp 2025 · 29 次引用
