Abstract
Smartwatches or fitness trackers have garnered a lot of popularity as potential health tracking devices due to their affordable and longitudinal monitoring capabilities. To further widen their health tracking capabilities, in recent years researchers have started to look into the possibility of Atrial Fibrillation (AF) detection in real-time leveraging photoplethysmography (PPG) data, an inexpensive sensor widely available in almost all smartwatches. A significant challenge in AF detection from PPG signals comes from the inherent noise in the smartwatch PPG signals. In this paper, we propose a novel deep learning based approach, BayesBeat that leverages the power of Bayesian deep learning to accurately infer AF risks from noisy PPG signals, and at the same time provides an uncertainty estimate of the prediction. Extensive experiments on two publicly available dataset reveal that our proposed method BayesBeat outperforms the existing state-of-the-art methods. Moreover, BayesBeat is substantially more efficient having 40--200X fewer parameters than state-of-the-art baseline approaches making it suitable for deployment in resource constrained wearable devices.
Ask Lune
Know this paper in minutes, not an afternoon.
Lune can read every page of it and the top-tier papers that cite it, and gives you its claims, its evidence and its limits, each one cited to the paper it comes from. No skimming, no AI slop.
Lineage
Builds on1
Related papers
- Towards Early Detection and Burden Estimation of Atrial Fibrillation in an Ambulatory Free-living EnvironmentHanbin Zhang, Li Zhu, Viswam Nathan, Jilong Kuang et al.UbiComp 2021 · 10 citations
- Know Me by My Pulse: Toward Practical Continuous Authentication on Wearable Devices via Wrist-Worn PPGWei Shao, Zequan Liang, Ruoyu Zhang, Ruijie Fang et al.NDSS 2026 · 7 citations
- Respiration Rate Estimation via Smartwatch-based Photoplethysmography and Accelerometer Data: A Transfer Learning ApproachKianoosh Kazemi, Iman Azimi, Pasi Liljeberg, Amir M. RahmaniUbiComp 2025 · 7 citations
- Crisp-BP: continuous wrist PPG-based blood pressure measurementYetong Cao, Huijie Chen, Fan Li, Yu WangMobiCom 2021 · 56 citations
- UWB-enabled Sensing for Fast and Effortless Blood Pressure MonitoringZhi Wang, Beihong Jin, Fusang Zhang, Siheng Li et al.UbiComp 2024 · 20 citations