Crisp-BP: continuous wrist PPG-based blood pressure measurement
Abstract
Arterial blood pressure (ABP) monitoring using wearables has emerged as a promising approach to empower users with self-monitoring for effective diagnosis and control of hypertension. However, existing schemes mainly monitor ABP at discrete time intervals, involve some form of user effort, have insufficient accuracy, and require collecting sufficient training data for model development. To tackle these problems, we propose Crisp-BP, a novel ABP monitoring system leveraging the PPG sensor available in commercial wrist-worn devices (e.g., smartwatches or fitness trackers). It enables continuous, accurate, user-independent ABP monitoring and requires no behavior changes during collecting PPG data. The basic idea is to illuminate a skin/tissue, measure the light absorption, and characterize ABP-related blood volume change in the artery. To obtain accurate measurements and relieve the pain of training data collection, we use an arterial pulse extraction method that removes interference caused by capillary pulses. Moreover, we design a contact pressure estimation method to combat the deficiency of PPG waveform being sensitive to the contact pressure between the sensor and the skin. In addition, we leverage the great power of Bidirectional Long Short Term Memory and design a hybrid neural network model to enable user-independent ABP monitoring, so that users do not have to provide training data for model development. Furthermore, we propose a transfer learning method that first extracts general knowledge from online PPG data, then use it to improve the learning of a new model on our target problem. Extensive experiments with 35 participants demonstrate that Crisp-BP obtains the average estimation error of 0.86 mmHg and 1.67 mmHg and the standard deviation error of 6.55 mmHg and 7.31 mmHg for diastolic pressure and systolic pressure, respectively. These errors are within the acceptable range regulated by the FDA's AAMI protocol, which allows average errors of up to 5 mmHg and a standard deviation of up to 8 mmHg. Our results demonstrate that Crisp-BP is promising for improving the diagnosis and control of hypertension as it provides continuousness, comfort, convenience, and accuracy.
Ask Lune
Know this paper in minutes, not an afternoon.
Lune can read every page of it and the top-tier papers that cite it, and gives you its claims, its evidence and its limits, each one cited to the paper it comes from. No skimming, no AI slop.
8 top-tier papers have cited it since. Know what they found before your reviewers do.
Lune can draw on
the full paper · the top-tier papers that cite it · related work
Free to start. No credit card required.
Lineage
- Guard Your Heart Silently: Continuous Electrocardiogram Waveform Monitoring with Wrist-Worn Motion Sensor cites PPGPass: Nonintrusive and Secure Mobile Two-Factor Authentication via Wearables
- PPGSpotter: Personalized Free Weight Training Monitoring Using Wearable PPG Sensor cites PPGPass: Nonintrusive and Secure Mobile Two-Factor Authentication via Wearables
Cited by top-tier papers8
- MoVi-Fi: motion-robust vital signs waveform recovery via deep interpreted RF sensingZhe Chen, Tianyue Zheng, Chao Cai, Jun LuoMobiCom 2021 · 190 citations
- Guard Your Heart Silently: Continuous Electrocardiogram Waveform Monitoring with Wrist-Worn Motion SensorYetong Cao, Fan Li, Huijie Chen, Xiaochen Liu et al.UbiComp 2022 · 19 citations
- LiT: Fine-grained Toothbrushing Monitoring with Commercial LED ToothbrushKaixin Chen, Lei Wang, Yongzhi Huang, Kaishun Wu et al.MobiCom 2023 · 13 citations
- HearBP: Hear Your Blood Pressure via In-ear Acoustic Sensing Based on Heart SoundsZhiyuan Zhao, Fan Li, Yadong Xie, Huanran Xie et al.INFOCOM 2024 · 11 citations
- PPGSpotter: Personalized Free Weight Training Monitoring Using Wearable PPG SensorXiaochen Liu, Fan Li, Yetong Cao, Shengchun Zhai et al.INFOCOM 2024 · 4 citations
Builds on2
- MoVi-Fi: motion-robust vital signs waveform recovery via deep interpreted RF sensingZhe Chen, Tianyue Zheng, Chao Cai, Jun LuoMobiCom 2021 · 190 citations
- PPGPass: Nonintrusive and Secure Mobile Two-Factor Authentication via WearablesYetong Cao, Qian Zhang, Fan Li, Song Yang et al.INFOCOM 2020 · 56 citations
Related papers
- RingBP: Towards Continuous, Comfortable, and Generalized Blood Pressure Monitoring Using a Smart RingGuanzhou Zhu, Dong Zhao, Yixuan Song, Zilong Wang et al.UbiComp 2025 · 2 citations
- UWB-enabled Sensing for Fast and Effortless Blood Pressure MonitoringZhi Wang, Beihong Jin, Fusang Zhang, Siheng Li et al.UbiComp 2024 · 20 citations
- MuBP: Multimodel and Continuous Blood Pressure Measurement via UWB-IMU Fusion on Commercial SmartwatchesDongzi Wang, Zhengxin Guo, Linqing Gui, Ming Gao et al.INFOCOM 2026
- PracticalBP: Continuous Cuffless Blood Pressure Monitoring with Only One Record for CalibrationChenggao Li, Junyao Peng, Qingyong Hu, Lin Chen et al.UbiComp 2025 · 3 citations
- Contactless Arterial Blood Pressure Waveform Monitoring with mmWave RadarQingyong Hu, Qian Zhang, Hao Lu, Shun Wu et al.UbiComp 2025 · 29 citations