HearBP: Hear Your Blood Pressure via In-ear Acoustic Sensing Based on Heart Sounds
Zhiyuan Zhao, Fan Li, Yadong Xie, Huanran Xie, Kerui Zhang, Li Zhang, Yu Wang
Abstract
Continuous blood pressure (BP) monitoring using wearable devices has received increasing attention due to its importance in diagnosing diseases. However, existing methods mainly measure BP intermittently, involve some form of user effort, and suffer from insufficient accuracy due to sensor properties. In order to overcome these limitations, we study the BP measurement technology based on heart sounds, and find that the time interval between the first and second heart sounds (TIFS) of bone-conducted heart sounds collected in the binaural canal is closely related to BP. Motivated by this, we propose HearBP, a novel BP monitoring system that utilizes inear microphones to collect bone-conducted heart sounds in the binaural canal. We first design a noise removing method based on U-net autoencoder-decoder to separate clean heart sounds from background noises. Then, we design a feature extraction method based on shannon energy and energy-entropy ratio to further mine the time domain and frequency domain features of heart sounds. In addition, combined with the principal component analysis algorithm, we achieve feature dimension reduction to extract the main features related to BP. Finally, we propose a network model based on dendritic neural regression to construct a mapping between the extracted features and BP. Extensive experiments with 41 participants show the average estimation error of 0.97mmHg and 1.61mmHg and the standard deviation error of 3.13mmHg and 3.56mmHg for diastolic pressure and systolic pressure, respectively. These errors are within the acceptable range specified by the FDA’s AAMI protocol.
Ask about this paper
Ask your agent about it.
Lune has read the top-tier papers around this one, so every answer names the papers it rests on.
Your agent calls
Lunesearch_papers
Free to start. No credit card required.
Terminal
Install the CLIlune papers get c6759cc5-0584-4aa9-a206-b05c7d98a5f5Cited by top-tier papers1
Ask how each one uses itRelated papers
- Continuous Pulmonary Artery Pressure Monitoring using In-ear MicrophoneJunyi Zhou, Chaoyi Sun, Di Fan, Yiyi Zhang et al.INFOCOM 2026
- HeartPrint: Passive Heart Sounds Authentication Exploiting In-Ear MicrophonesYetong Cao, Chao Cai, Fan Li, Zhe Chen et al.INFOCOM 2023 · 29 citations
- UWB-enabled Sensing for Fast and Effortless Blood Pressure MonitoringZhi Wang, Beihong Jin, Fusang Zhang, Siheng Li et al.UbiComp 2024 · 20 citations
- Crisp-BP: continuous wrist PPG-based blood pressure measurementYetong Cao, Huijie Chen, Fan Li, Yu WangMobiCom 2021 · 56 citations
- ArtEARial: Arterial Pressure Waveform Reconstruction Using Earbud AudioKenneth Christofferson, Michelle Lin, Joseph A. Cafazzo, Alex MariakakisUbiComp 2026
