hBP-Fi: Contactless Blood Pressure Monitoring via Deep-Analyzed Hemodynamics
Yetong Cao, Shujie Zhang, Fan Li, Zhe Chen, Jun Luo
Abstract
Blood pressure (BP) measurement is significant to the assessment of many dangerous health conditions. Apart from invasively inserting catheters into arteries, non-invasive approaches typically rely on wearing devices on specific skin areas with consistent pressure. However, this can be uncomfortable and unsuitable for certain individuals, and the accuracy of these methods may significantly decrease due to improper device placements and wearing states. Recently, contactless methods leveraging RF technology have emerged as a potential alternative. However, these methods suffer from the drawback of overfitting deep learning (DL) models without a sound physiological basis, resulting in a lack of clear explanations for their outputs. Consequently, such limitations lead to skepticism and distrust among medical experts. In this paper, we propose hBP-Fi, a contactless BP measurement system driven by hemodynamics acquired via RF sensing. In addition to its contactless convenience, hBP-Fi is superior to other RF sensing approaches in i) grounding on hemodynamics as the key physical process of heart-pulse activities, ii) exploiting beam-steerable RF devices to achieve a super-resolution scan on the fine-grained pulse activities along arm arteries, and iii) ensuring the trustworthiness of system outputs via an explainable (decision-understandable) DL model. Extensive experiments with 35 subjects demonstrate that hBP-Fi can achieve the error of -2.05±6.83 mmHg and 1.99 ± 6.30 mmHg for monitoring systolic and diastolic blood pressures, respectively.
Ask about this paper
Ask your agent about it.
Lune has read the top-tier papers around this one, so every answer names the papers it rests on.
Your agent calls
Lunesearch_papers
Free to start. No credit card required.
Terminal
Install the CLIlune papers get 7077cc3b-176d-463f-91be-8ad4119b0d95Related papers
- UWB-enabled Sensing for Fast and Effortless Blood Pressure MonitoringZhi Wang, Beihong Jin, Fusang Zhang, Siheng Li et al.UbiComp 2024 · 20 citations
- Crisp-BP: continuous wrist PPG-based blood pressure measurementYetong Cao, Huijie Chen, Fan Li, Yu WangMobiCom 2021 · 56 citations
- RF-AE: Single-site Arterial Elasticity Estimation Using UWB SignalsZhi Wang, Beihong Jin, Yuhui Chen, Fusang Zhang et al.UbiComp 2025 · 1 citation
- FewShotBP: Towards Personalized Ubiquitous Continuous Blood Pressure MeasurementFeiyi Fan, Yang Gu, Jianfei Shen, Fan Dong et al.UbiComp 2023 · 18 citations
- PracticalBP: Continuous Cuffless Blood Pressure Monitoring with Only One Record for CalibrationChenggao Li, Junyao Peng, Qingyong Hu, Lin Chen et al.UbiComp 2025 · 3 citations
