DuBCG: Unlocking In-Home, Clinically Comparable mmWave Cardiac Monitoring for Co-Sleepers via Physics-Informed Spatial Sensing
Xusheng Zhang, Duo Zhang, Jingfu Dong, Ruiqi Yu, Hongliu Yang, Junzhe Wang, Zizhou Fan, Zhehui Yin, Daqing Zhang
摘要
Continuous, fine-grained cardiac monitoring during sleep is vital for cardiovascular health. Emerging as a promising alternative to cumbersome wearables, mmWave radar offers a contactless, privacy-preserving modality capable of capturing minute skin vibrations. However, transitioning mmWave radar from labs to real-world bedrooms remains challenging. Our rigorous empirical evaluation of state-of-the-art systems reveals a severe reliability gap: valid Inter-Beat Intervals (IBI) are captured for only 24%-42% of the night within an error threshold of 50 ms. Since clinical HRV analysis requires millisecond-level precision (e.g., RMSSD changes), such coarse and intermittent tracking renders existing methods medically insufficient. We attribute this failure to two fundamental hurdles: (i) instability driven by overwhelming respiratory interference and postural diversity, and (ii) signal entanglement in co-sleeping scenarios where angular separation defies hardware resolution. To bridge this gap, we present DuBCG. First, to tackle instability, we introduce a Head-Facing configuration to capture the Radar Ballistocardiogram (R-BCG). By leveraging the body's longitudinal recoil, this approach achieves orthogonal respiratory suppression and posture-invariant robustness. Second, to resolve entanglement, we propose the Multi-point Scattering Spatial Selectivity Model, theoretically proving that signal separability is achievable beyond physical resolution limits. Extensive real-world benchmarks demonstrate that DuBCG achieves a median IBI error of 8.4 ms—an 8× improvement over existing methods. This precision bridges the gap from existing intermittent monitoring to long-term, clinically comparable continuous HRV assessment.
问问这篇 Paper
问问你的智能体。
Lune 读过与它相关的顶会 Paper,每个回答都会注明依据哪几篇。
相关 Paper
- Breaking the Resolution Barriers of mmWave Arrays via Null Steering for Sleep Monitoring in Multi-Person ScenariosDuo Zhang, Xusheng Zhang, Zhehui Yin, Pengfei Zhou 等UbiComp 2025 · 被引用 10 次
- DailyBeat: Reliable Cardiac Sensing Under Self-Induced Dynamic Interference Using mmWave RadarZhaoxin Chang, Pei Wang, Xujun Ma, Fusang Zhang 等UbiComp 2026
- RaECG: mmWave Radar-based Electrocardiogram Monitoring Using Chest Vibration and Carotid PulseJiefan Qiu, Mengqi Jiang, Kaikai Chi, Jiajia Liu 等INFOCOM 2026 · 被引用 1 次
- mmECG: Monitoring Human Cardiac Cycle in Driving Environments Leveraging Millimeter WaveXiangyu Xu, Jiadi Yu, Chengguang Ma, Yanzhi Ren 等INFOCOM 2022 · 被引用 63 次
- Finding Order in Chaos: Learning Disentangled Features for mmWave Cardiac SensingFulong Liu, Jinbo Chen, Haoyu Wang, Hanqin Gong 等UbiComp 2026 · 被引用 3 次
