Heat Behind the Meter: A Hidden Threat of Thermal Attacks in Edge Colocation Data Centers

Zhihui Shao, Mohammad A. Islam, Shaolei Ren

摘要

The widespread adoption of Internet of Things and latency-critical applications has fueled the burgeoning development of edge colocation data centers (a.k. a., edge colocation) — small-scale data centers in distributed locations. In an edge colocation, multiple entities/tenants house their own physical servers together, sharing the power and cooling infrastructures for cost efficiency and scalability. In this paper, we discover that the sharing of cooling systems also exposes edge colocations’ potential vulnerabilities to cooling load injection attacks (called thermal attacks) by an attacker which, if left at large, may create thermal emergencies and even trigger system outages. Importantly, thermal attacks can be launched by leveraging the emerging architecture of built-in batteries integrated with servers that can conceal the attacker’s actual server power (or cooling load). We consider both one-shot attacks (which aim at creating system outages) and repeated attacks (which aim at causing frequent thermal emergencies). For repeated attacks, we present a foresighted attack strategy which, using reinforcement learning, learns on the fly a good timing for attacks based on the battery state and benign tenants’ load. We also combine prototype experiments with simulations to validate our attacks and show that, for a small 8kW edge colocation, an attacker can potentially cause significant losses. Finally, we suggest effective countermeasures to the potential threat of thermal attacks.

问 Lune

几分钟读透这篇 Paper,不用再花一下午。

Lune 能读完全文,也能读引用它的顶会 Paper,讲清它的结论、证据和局限,每一点都注明出自哪篇 Paper。不用硬啃,也不靠猜。

可以从这些问题问起

Lune 可以查阅

全文 · 相关的 Paper

获取答案

免费开始,无需绑卡

脉络

  • Reduced Cooling Redundancy: A New Security Vulnerability in a Hot Data Center 引用了 Exploiting a Thermal Side Channel for Power Attacks in Multi-Tenant Data Centers
它引用的引用它的从左到右按年份排列,引用越多,位置越高。

它引用的 Paper7

  1. Prediction-Based Power Oversubscription in Cloud PlatformsAlok Gautam Kumbhare, Reza Azimi, Ioannis Manousakis, Anand Bonde 等USENIX ATC 2021 · 90 次引用
  2. Data Center Power Oversubscription with a Medium Voltage Power Plane and Priority-Aware CappingVarun Sakalkar, Vasileios Kontorinis, David Landhuis, Shaohong Li 等ASPLOS 2020 · 56 次引用
  3. Exploiting a Thermal Side Channel for Power Attacks in Multi-Tenant Data CentersMohammad A. Islam, Shaolei Ren, Adam WiermanCCS 2017 · 53 次引用
  4. Vehicular and Edge Computing for Emerging Connected and Autonomous Vehicle ApplicationsSabur Baidya, Yu-Jen Ku, Hengyu Zhao, Jishen Zhao 等DAC 2020 · 37 次引用
  5. Reduced Cooling Redundancy: A New Security Vulnerability in a Hot Data CenterXing Gao, Zhang Xu, Haining Wang, Li Li 等NDSS 2018 · 32 次引用

相关 Paper

  1. Ohm's Law in Data Centers: A Voltage Side Channel for Timing Power AttacksMohammad A. Islam, Shaolei RenCCS 2018 · 27 次引用
  2. Repttack: Exploiting Cloud Schedulers to Guide Co-Location AttacksChongzhou Fang, Han Wang, Najmeh Nazari, Behnam Omidi 等NDSS 2022
  3. Everywhere All at Once: Co-Location Attacks on Public Cloud FaaSZirui Neil Zhao, Adam Morrison, Christopher W. Fletcher, Josep TorrellasASPLOS 2024 · 16 次引用
  4. Data Center Cooling System Optimization Using Offline Reinforcement LearningXianyuan Zhan, Xiangyu Zhu, Peng Cheng, Xiao Hu 等ICLR 2025
  5. Worst-Case Attacks in Reactive Edge-Cloud Systems: Expected Latency and SLA ViolationJhonatan Tavori, Mehmet Kerem Türkcan, Zoran Kostic, Javad Ghaderi 等INFOCOM 2026 · 1 次引用
黄昏的海面,两侧是细线勾勒的悬崖