Detection of Artifacts in Ambulatory Electrodermal Activity Data
Shkurta Gashi, Elena Di Lascio, Bianca Stancu, Vedant Das Swain, Varun Mishra, Martin Gjoreski, Silvia Santini
摘要
Recent wearable devices enable continuous and unobtrusive monitoring of human's physiological parameters, like e.g., electrodermal activity and heart rate, over long periods of time in everyday life settings. Continuous monitoring of these parameters enables the creation of systems able to predict affective states and stress with the goal of providing feedback to improve them. Deployment of such systems in everyday life settings is still complex and prone to errors due to the low quality of the collected data impacted by the presence of artifacts. In this paper we present an automatic approach to detect artifacts in electrodermal activity (EDA) signals collected in-the-wild over long periods of time. To this end we first perform a systematic literature review and compile a set of guidelines for human annotators to label artifacts manually and we use these labels as ground-truth to test our automatic approach. To evaluate our approach, we collect physiological data from 13 participants in-the-wild and two human annotators label 107.56 hours of this data set. We make the data set publicly available to other researchers upon request. Our model achieves a recall of 98% for clean and shape artifacts classification on data collected in-the-wild using leave-one-subject-out cross-validation, which is 42 percentage points higher than the baseline. We show that state of the art approaches do not generalize well when tested with completely in-the-wild data and identify only 17% of the artifacts present in our data set, even after manual adaption. We further test the robustness of our approach over time using leave-one-day-out and achieve very similar performance. We then introduce a new metric to evaluate the quality of EDA segments that considers the impact of not only artifacts in the shape of EDA but also artifacts generated by environmental temperature changes or user's high intensity movement. Our results imply that we can eliminate the need for human annotators or significantly reduce the time they need to label data. Also, our approach can be used in an online manner to automatically detect artifacts in EDA signals.
问 Lune
几分钟读透这篇 Paper,不用再花一下午。
Lune 能读完全文,也能读引用它的顶会 Paper,讲清它的结论、证据和局限,每一点都注明出自哪篇 Paper。不用硬啃,也不靠猜。
已有 1 篇顶会 Paper 引用了它。别等审稿人问起,先弄清它们发现了什么。
脉络
引用它的顶会 Paper1
相关 Paper
- Lateralization Effects in Electrodermal Activity Data Collected Using Wearable DevicesLeonardo Alchieri, Nouran Abdalazim, Lidia Alecci, Shkurta Gashi 等UbiComp 2024 · 6 次引用
- Semi-Supervised Learning for Wearable-based Momentary Stress Detection in the WildHan Yu, Akane SanoUbiComp 2023 · 22 次引用
- Heartbeats in the Wild: A Field Study Exploring ECG Biometrics in Everyday LifeFlorian Lehmann, Daniel BuschekCHI 2020 · 15 次引用
- Sweating the Details: Emotion Recognition and the Influence of Physical Exertion in Virtual Reality ExergamingDominic Potts, Zoe Broad, Tarini Sehgal, Joseph Hartley 等CHI 2024 · 14 次引用
- Captivates: A Smart Eyeglass Platform for Across-Context Physiological MeasurementPatrick Chwalek, David B. Ramsay, Joseph A. ParadisoUbiComp 2021 · 20 次引用
