Heat to Power: Thermal Energy Harvesting and Recycling for Warm Water-Cooled Datacenters
Xinhui Zhu, Weixiang Jiang, Fangming Liu, Qixia Zhang, Li Pan, Qiong Chen, Ziyang Jia
Abstract
Warm water cooling has been regarded as a promising method to improve the energy efficiency of water-cooled datacenters. In warm water-cooling systems, hot spots occur as a common problem where the hybrid cooling architecture integrating thermoelectric coolers (TECs) emerges as a new remedy. Equipped with this architecture, the inlet water temperature can be raised higher, which provides more opportunities for heat recycling. However, currently, the heat absorbed from the server components is ejected directly into the water without being recycled, which leads to energy wasting. In order to further improve the energy efficiency, we propose Heat to Power (H2P), an economical and energy-recycling warm water cooling architecture, where thermoelectric generators (TEGs) harvest thermal energy from the “used” warm water and generate electricity for reusing in datacenters. Specifically, we propose some efficient optimization methods, including an economical water circulation design, fine-grained adjustments of the cooling setting and dynamic workload scheduling for increasing the power generated by TEGs. We evaluate H2P based on a real hardware prototype and cluster traces from Google and Alibaba. Experiment results show that TEGs equipped with our optimization methods can averagely generate 4.349 W, 4.203 W, and 3.979 W (4.177 W averagely) electricity on one CPU under the drastic, irregular and common workload traces, respectively. The power reusing efficiency (PRE) can reach 12.8% 16.2% (14.23% averagely) and the total cost of ownership (TCO) of datacenters can be reduced by up to 0.57%.
Ask about this paper
Your agent reads all of it.
Lune indexed this paper to the last equation, along with the top-tier papers that cite it. Ask a question and the answer quotes them.
Your agent calls
Luneget_paper_fulltext
Free to start. No credit card required.
Terminal
Install the CLIlune papers fulltext 0dc22e50-28e8-42a2-9717-a5096b797aecCited by top-tier papers1
Ask how each one uses itRelated papers
- Soil-Monitoring Sensor Powered by Temperature Difference between Air and Shallow Underground SoilNatsuki Ikeda, Ryo Shigeta, Junichiro Shiomi, Yoshihiro KawaharaUbiComp 2020 · 39 citations
- Data Center Cooling System Optimization Using Offline Reinforcement LearningXianyuan Zhan, Xiangyu Zhu, Peng Cheng, Xiao Hu et al.ICLR 2025
- UPTPU: Improving Energy Efficiency of a Tensor Processing Unit through Underutilization Based Power-GatingPramesh Pandey, Noel Daniel Gundi, Koushik Chakraborty, Sanghamitra RoyDAC 2021 · 10 citations
- Cost-Efficient Overclocking in Immersion-Cooled DatacentersMajid Jalili, Ioannis Manousakis, Iñigo Goiri, Pulkit A. Misra et al.ISCA 2021 · 54 citations
- AgileWatts: An Energy-Efficient CPU Core Idle-State Architecture for Latency-Sensitive Server ApplicationsJawad Haj-Yahya, Haris Volos, Davide B. Bartolini, Georgia Antoniou et al.MICRO 2022 · 22 citations